D-Library Repositry

//uquui/

Reports Community

Annual Report Collection

 2019

 Failure Analysis of Flue Gas Duct in a Steam Power Plant

 Mohammad E.Habash


//uquui/handle/20.500.12248/116027
0 Downloads
958 Visits

Failure Analysis of Flue Gas Duct in a Steam Power Plant

Alternative : Master Degree
Call Number : 23572
Publisher :جامعة أم القرى
Pub Place : مكة المكرمة
Issue Date : 2019 - 1440 H
Description : 70 paper
Format : ماجستير
Language : عربي
Is format of : مكتبة الملك عبدالله بن عبدالعزيز الجامعية

Power plant consists of systems that affect each other. The main two cycles in power plant are Water – Steam and Air – Gas cycles. Flue gas duct is used in air-gas cycle to release the flue gas from the furnace to the atmosphere. The cracks and holes occur in the gas duct as a result of corrosion, which resulted in allowing the air ingress into the duct and consequently cause a chemical reaction with flue gas, this reaction creates a sulfuric acid layer and hence accumulate on the internal surfaces of the duct and transfer to Induced Draft Fan (IDF). The main objective of this work is to introduce a composite layer to Corten Steel (the material from which the gas duct made) to improve a corrosion resistance. This coating layer consists from serval nanoparticles (ZnO, ZrO2, SiO2 and NiO) as reinforcement phase with epoxy resins matrix. The surface roughness profiles of Nano-epoxy composite coating show an improvement in surface roughness compared to the original corten steel without coating. Furthermore, XRF and XRD analysis shows the Nano-epoxy composite coating elements and the increment of element that improve corrosion resistance.

Title: Failure Analysis of Flue Gas Duct in a Steam Power Plant
Other Titles: Master Degree
Authors: Mohamed K. Hassan
Mohammad E.Habash
Issue Date :: 2019
Publisher :: جامعة أم القرى
Abstract: Power plant consists of systems that affect each other. The main two cycles in power plant are Water – Steam and Air – Gas cycles. Flue gas duct is used in air-gas cycle to release the flue gas from the furnace to the atmosphere. The cracks and holes occur in the gas duct as a result of corrosion, which resulted in allowing the air ingress into the duct and consequently cause a chemical reaction with flue gas, this reaction creates a sulfuric acid layer and hence accumulate on the internal surfaces of the duct and transfer to Induced Draft Fan (IDF). The main objective of this work is to introduce a composite layer to Corten Steel (the material from which the gas duct made) to improve a corrosion resistance. This coating layer consists from serval nanoparticles (ZnO, ZrO2, SiO2 and NiO) as reinforcement phase with epoxy resins matrix. The surface roughness profiles of Nano-epoxy composite coating show an improvement in surface roughness compared to the original corten steel without coating. Furthermore, XRF and XRD analysis shows the Nano-epoxy composite coating elements and the increment of element that improve corrosion resistance.
Description :: 70 paper
URI: https://dorar.uqu.edu.sa/uquui/handle/20.500.12248/116027
Appears in Collections :الرسائل العلمية المحدثة

Files in This Item :
File Description SizeFormat 
Failure Analysis of Flue Gas Duct in A Power Plant _Final ver_Mohammad Habash.pdf
"   Restricted Access"
الرسالة الكاملة5.78 MBAdobe PDFView/Open
Request a copy
title.pdf
"   Restricted Access"
غلاف94.49 kBAdobe PDFView/Open
Request a copy
abse.pdf
"   Restricted Access"
ملخص الرسالة بالإنجليزي155.13 kBAdobe PDFView/Open
Request a copy
ind.pdf
"   Restricted Access"
المقدمة1.48 MBAdobe PDFView/Open
Request a copy
cont.pdf
"   Restricted Access"
فهرس الموضوعات282.64 kBAdobe PDFView/Open
Request a copy
Add to Auditors PDF citation Digitization Request

Comments (0)



Items in D-Library are protected by copyright, with all rights reserved, unless otherwise indicated.