dc.description | 70 paper | en_US |
dc.description.abstract | Power plant consists of systems that affect each other. The main two cycles in power plant are Water – Steam and Air – Gas cycles. Flue gas duct is used in air-gas cycle to release the flue gas from the furnace to the atmosphere. The cracks and holes occur in the gas duct as a result of corrosion, which resulted in allowing the air ingress into the duct and consequently cause a chemical reaction with flue gas, this reaction creates a sulfuric acid layer and hence accumulate on the internal surfaces of the duct and transfer to Induced Draft Fan (IDF). The main objective of this work is to introduce a composite layer to Corten Steel (the material from which the gas duct made) to improve a corrosion resistance. This coating layer consists from serval nanoparticles (ZnO, ZrO2, SiO2 and NiO) as reinforcement phase with epoxy resins matrix. The surface roughness profiles of Nano-epoxy composite coating show an improvement in surface roughness compared to the original corten steel without coating. Furthermore, XRF and XRD analysis shows the Nano-epoxy composite coating elements and the increment of element that improve corrosion resistance. | en_US |
dc.language.iso | عربي | en_US |
dc.publisher | جامعة أم القرى | en_US |
dc.relation.isformatof | مكتبة الملك عبدالله بن عبدالعزيز الجامعية | en_US |
dc.subject.other | Mechanical engineering | - |
dc.subject.other | Power plant | - |
dc.title | Failure Analysis of Flue Gas Duct in a Steam Power Plant | en_US |
dc.title.alternative | Master Degree | en_US |
dc.identifier.callnum | 23572 | - |
dc.type.format | ماجستير | en_US |
dc.publisher.country | المملكة العربية السعودية | en_US |
dc.relation.collage | الهندسة والعمارة الإسلامية | en_US |
dc.type.status | مجاز | en_US |
dc.publisher.city | مكة المكرمة | en_US |
dc.date.issuedhijri | 1440 | en_US |
dc.relation.dep | الهندسة الميكانيكية | en_US |
Appears in Collections : | الرسائل العلمية المحدثة |
Files in This Item :
File | Description | Size | Format | |
---|---|---|---|---|
Failure Analysis of Flue Gas Duct in A Power Plant _Final ver_Mohammad Habash.pdf " Restricted Access" | الرسالة الكاملة | 5.78 MB | Adobe PDF | View/OpenRequest a copy |
title.pdf " Restricted Access" | غلاف | 94.49 kB | Adobe PDF | View/OpenRequest a copy |
abse.pdf " Restricted Access" | ملخص الرسالة بالإنجليزي | 155.13 kB | Adobe PDF | View/OpenRequest a copy |
ind.pdf " Restricted Access" | المقدمة | 1.48 MB | Adobe PDF | View/OpenRequest a copy |
cont.pdf " Restricted Access" | فهرس الموضوعات | 282.64 kB | Adobe PDF | View/OpenRequest a copy |
Items in D-Library are protected by copyright, with all rights reserved, unless otherwise indicated.
Comments (0)