المستودع الرقمى

//uquui/

تقرير الوحدة

تقرير المجموعة

 2019

 Failure Analysis of Flue Gas Duct in a Steam Power Plant

 Mohammad E.Habash


//uquui/handle/20.500.12248/116027
0 التحميل
954 المشاهدات

Failure Analysis of Flue Gas Duct in a Steam Power Plant

عناوين أخرى : Master Degree
المؤلفون : Mohammad E.Habash
رقم الطلب : 23572
الناشر :جامعة أم القرى
مكان النشر : مكة المكرمة
تاريخ النشر : 2019 - 1440 هـ
الوصف : 70 paper
نوع الوعاء : ماجستير
اللغة : عربي
المصدر : مكتبة الملك عبدالله بن عبدالعزيز الجامعية
يظهر في المجموعات : الرسائل العلمية المحدثة

Power plant consists of systems that affect each other. The main two cycles in power plant are Water – Steam and Air – Gas cycles. Flue gas duct is used in air-gas cycle to release the flue gas from the furnace to the atmosphere. The cracks and holes occur in the gas duct as a result of corrosion, which resulted in allowing the air ingress into the duct and consequently cause a chemical reaction with flue gas, this reaction creates a sulfuric acid layer and hence accumulate on the internal surfaces of the duct and transfer to Induced Draft Fan (IDF). The main objective of this work is to introduce a composite layer to Corten Steel (the material from which the gas duct made) to improve a corrosion resistance. This coating layer consists from serval nanoparticles (ZnO, ZrO2, SiO2 and NiO) as reinforcement phase with epoxy resins matrix. The surface roughness profiles of Nano-epoxy composite coating show an improvement in surface roughness compared to the original corten steel without coating. Furthermore, XRF and XRD analysis shows the Nano-epoxy composite coating elements and the increment of element that improve corrosion resistance.

العنوان: Failure Analysis of Flue Gas Duct in a Steam Power Plant
عناوين أخرى: Master Degree
المؤلفون: Mohamed K. Hassan
Mohammad E.Habash
تاريخ النشر :: 2019
الناشر :: جامعة أم القرى
الملخص: Power plant consists of systems that affect each other. The main two cycles in power plant are Water – Steam and Air – Gas cycles. Flue gas duct is used in air-gas cycle to release the flue gas from the furnace to the atmosphere. The cracks and holes occur in the gas duct as a result of corrosion, which resulted in allowing the air ingress into the duct and consequently cause a chemical reaction with flue gas, this reaction creates a sulfuric acid layer and hence accumulate on the internal surfaces of the duct and transfer to Induced Draft Fan (IDF). The main objective of this work is to introduce a composite layer to Corten Steel (the material from which the gas duct made) to improve a corrosion resistance. This coating layer consists from serval nanoparticles (ZnO, ZrO2, SiO2 and NiO) as reinforcement phase with epoxy resins matrix. The surface roughness profiles of Nano-epoxy composite coating show an improvement in surface roughness compared to the original corten steel without coating. Furthermore, XRF and XRD analysis shows the Nano-epoxy composite coating elements and the increment of element that improve corrosion resistance.
الوصف :: 70 paper
الرابط: https://dorar.uqu.edu.sa/uquui/handle/20.500.12248/116027
يظهر في المجموعات :الرسائل العلمية المحدثة

الملفات في هذا العنصر:
ملف الوصف الحجمالتنسيق 
Failure Analysis of Flue Gas Duct in A Power Plant _Final ver_Mohammad Habash.pdf
"   الوصول المحدود"
الرسالة الكاملة5.78 MBAdobe PDFعرض/ فتح
طلب نسخة
title.pdf
"   الوصول المحدود"
غلاف94.49 kBAdobe PDFعرض/ فتح
طلب نسخة
abse.pdf
"   الوصول المحدود"
ملخص الرسالة بالإنجليزي155.13 kBAdobe PDFعرض/ فتح
طلب نسخة
ind.pdf
"   الوصول المحدود"
المقدمة1.48 MBAdobe PDFعرض/ فتح
طلب نسخة
cont.pdf
"   الوصول المحدود"
فهرس الموضوعات282.64 kBAdobe PDFعرض/ فتح
طلب نسخة
اضف إلى مراجعى الاستشهاد المرجعي طلب رقمنة مادة

تعليقات (0)



جميع الأوعية على المكتبة الرقمية محمية بموجب حقوق النشر، ما لم يذكر خلاف ذلك