Design Optimization and Simulation of an Ice Plant Working by Solar Adsorption Technology
This project presents a design optimization of a solar adsorption ice plant using activated carbon and methanol as working pairs in the climate of Makkah to produce a ton of ice per day. The plant consists of six adsorption refrigeration units. Each unit has 61 separate cylindrical adsorbent beds connected with its own condenser, valve, and evaporator. The unit is heated by seven evacuated-tube collectors connected in parallel. The total number of collectors are 42 collectors. The beds are filled by estimated amount of 457.5 kg of activated carbon with 151 kg of methanol. Selection and dimensioning of each component were carried out based on previous recommended values. A mathematical model and simulation were developed to demonstrate the system performance along the year. The results showed that plant could produce up to ton of daily ice along the year. The coefficient of performance can reach 0.76 with condenser and evaporator temperatures of 35°C and -5°C respectively. The performance of the system is greatly affected by ambient temperature more than solar radiation. Therefore, the best performance and largest amount of ice was found in the winter season.
العنوان: | Design Optimization and Simulation of an Ice Plant Working by Solar Adsorption Technology |
المؤلفون: | عابدين, عادل العمودي, حسين عبدالله حسين |
الموضوعات :: | Solar Energy ice plants |
تاريخ النشر :: | 2021 |
الناشر :: | جامعة أم القرى |
الملخص: | This project presents a design optimization of a solar adsorption ice plant using activated carbon and methanol as working pairs in the climate of Makkah to produce a ton of ice per day. The plant consists of six adsorption refrigeration units. Each unit has 61 separate cylindrical adsorbent beds connected with its own condenser, valve, and evaporator. The unit is heated by seven evacuated-tube collectors connected in parallel. The total number of collectors are 42 collectors. The beds are filled by estimated amount of 457.5 kg of activated carbon with 151 kg of methanol. Selection and dimensioning of each component were carried out based on previous recommended values. A mathematical model and simulation were developed to demonstrate the system performance along the year. The results showed that plant could produce up to ton of daily ice along the year. The coefficient of performance can reach 0.76 with condenser and evaporator temperatures of 35°C and -5°C respectively. The performance of the system is greatly affected by ambient temperature more than solar radiation. Therefore, the best performance and largest amount of ice was found in the winter season. |
الوصف :: | 47 ورقة |
الرابط: | http://dorar.uqu.edu.sa//uquui/handle/20.500.12248/132272 |
يظهر في المجموعات : | الرسائل العلمية المحدثة |
ملف | الوصف | الحجم | التنسيق | |
---|---|---|---|---|
24949.pdf " الوصول المحدود" | الرسالة الكاملة | 2.2 MB | Adobe PDF | عرض/ فتحطلب نسخة |
title24949.pdf " الوصول المحدود" | غلاف | 91.97 kB | Adobe PDF | عرض/ فتحطلب نسخة |
absa24949.pdf " الوصول المحدود" | ملخص الرسالة بالعربي | 96.02 kB | Adobe PDF | عرض/ فتحطلب نسخة |
abse24949.pdf " الوصول المحدود" | ملخص الرسالة بالإنجليزي | 78.38 kB | Adobe PDF | عرض/ فتحطلب نسخة |
indu24949.pdf " الوصول المحدود" | المقدمة | 65.49 kB | Adobe PDF | عرض/ فتحطلب نسخة |
cont24949.pdf " الوصول المحدود" | فهرس الموضوعات | 184.59 kB | Adobe PDF | عرض/ فتحطلب نسخة |
جميع الأوعية على المكتبة الرقمية محمية بموجب حقوق النشر، ما لم يذكر خلاف ذلك
تعليقات (0)