D-Library Repositry

//uquui/

Reports Community

Annual Report Collection

 2021

 ضمان الجودة لأجهزة التشخيص الاشعاعي في المستشفيات

 راجحي, ياسمين عبدالله يحيى


//uquui/handle/20.500.12248/132133
0 Downloads
303 Visits

ضمان الجودة لأجهزة التشخيص الاشعاعي في المستشفيات

Alternative : Quality Assurance for Diagnostic X-ray Machines in Hospitals
Call Number : 42403
Publisher :جامعة أم القرى
Pub Place : مكة المكرمة
Issue Date : 2021 - 1442 H
Description : 98ورقة.
Format : ماجستير
Department : الفيزياء
Language : انجليزي
Is format of : مكتبة الملك عبدالله بن عبدالعزيز الجامعية

Using an accurate protocols from different associations, organizations, and committees (such as the American Association of Physicists in Medicine (AAPM), the American College of Medical Physics (ACPM), the American College of Nuclear Medicine (ACNM)… etc). Professionally made tools (such as the RaySafe and Fluke Biomedical) and phantoms (such as Pro-Digi phantom, Pro-fluo phantom, CT Dose phantom, CT ACR 464, Mammo 156 Phantom) are required to measure physical parameters of the machines accurately. These parameters include: kilovoltage peak (kVp) - exposure time accuracy and reproducibility - Mill-Ampere Second (mAs) linearity - half value layer (HVL) - typical entrance skin exposure rate (ESER) - collimator leakage - alignment light accuracy - image quality - CT number accuracy - CT number uniformity - slice thickness - low contrast resolution - high contrast resolution - radiation dosimetry - Automatic exposure control (AEC) thickness tracking -detector uniformity - Automatic exposure control (AEC) reproducibility - image quality -contrast noise ratio (CNR) - average glandular dose (AGD). Quality Control (QC) tests were performed in five local hospitals in Makkah city and all Image quality results for all modalities were within the accepted tolerance level. AGD of mammography, the effective dose of CT and typical patient entrance skin exposure rates of both fluoroscopy and C-arm were within the tolerance. Time accuracy in the ordinary X-ray for small focal spot size was -5.85% outside the limit and Mammography kVp accuracy maximum value also was 5.6% outside the limit for small focal spot size. Automatic exposure control (AEC) reproducibility Coefficient of variation (COV) results for mammography was 0.103 where the tolerance is COV < 0.05 and results were outside that.

Title: ضمان الجودة لأجهزة التشخيص الاشعاعي في المستشفيات
Other Titles: Quality Assurance for Diagnostic X-ray Machines in Hospitals
Authors: نتو, سمير سليمان أحمد
راجحي, ياسمين عبدالله يحيى
Subjects :: Medical Physics
Issue Date :: 2021
Publisher :: جامعة أم القرى
Abstract: Using an accurate protocols from different associations, organizations, and committees (such as the American Association of Physicists in Medicine (AAPM), the American College of Medical Physics (ACPM), the American College of Nuclear Medicine (ACNM)… etc). Professionally made tools (such as the RaySafe and Fluke Biomedical) and phantoms (such as Pro-Digi phantom, Pro-fluo phantom, CT Dose phantom, CT ACR 464, Mammo 156 Phantom) are required to measure physical parameters of the machines accurately. These parameters include: kilovoltage peak (kVp) - exposure time accuracy and reproducibility - Mill-Ampere Second (mAs) linearity - half value layer (HVL) - typical entrance skin exposure rate (ESER) - collimator leakage - alignment light accuracy - image quality - CT number accuracy - CT number uniformity - slice thickness - low contrast resolution - high contrast resolution - radiation dosimetry - Automatic exposure control (AEC) thickness tracking -detector uniformity - Automatic exposure control (AEC) reproducibility - image quality -contrast noise ratio (CNR) - average glandular dose (AGD). Quality Control (QC) tests were performed in five local hospitals in Makkah city and all Image quality results for all modalities were within the accepted tolerance level. AGD of mammography, the effective dose of CT and typical patient entrance skin exposure rates of both fluoroscopy and C-arm were within the tolerance. Time accuracy in the ordinary X-ray for small focal spot size was -5.85% outside the limit and Mammography kVp accuracy maximum value also was 5.6% outside the limit for small focal spot size. Automatic exposure control (AEC) reproducibility Coefficient of variation (COV) results for mammography was 0.103 where the tolerance is COV < 0.05 and results were outside that.
Description :: 98ورقة.
URI: http://dorar.uqu.edu.sa//uquui/handle/20.500.12248/132133
Appears in Collections :الرسائل العلمية المحدثة

Files in This Item :
File Description SizeFormat 
24403.pdf
"   Restricted Access"
الرسالة الكاملة22.19 MBAdobe PDFView/Open
Request a copy
title24403.pdf
"   Restricted Access"
غلاف197.65 kBAdobe PDFView/Open
Request a copy
absa24403.pdf
"   Restricted Access"
ملخص الرسالة بالعربي72.06 kBAdobe PDFView/Open
Request a copy
abse24403.pdf
"   Restricted Access"
ملخص الرسالة بالإنجليزي56.85 kBAdobe PDFView/Open
Request a copy
indu24403.pdf
"   Restricted Access"
المقدمة72.14 kBAdobe PDFView/Open
Request a copy
cont24403.pdf
"   Restricted Access"
فهرس الموضوعات191.58 kBAdobe PDFView/Open
Request a copy
Add to Auditors PDF citation Digitization Request

Comments (0)



Items in D-Library are protected by copyright, with all rights reserved, unless otherwise indicated.