المستودع الرقمى

//uquui/

تقرير الوحدة

تقرير المجموعة

 2021

 ضمان الجودة لأجهزة التشخيص الاشعاعي في المستشفيات

 راجحي, ياسمين عبدالله يحيى


//uquui/handle/20.500.12248/132133
تسجيلة بيانات وصفية كاملة
حقل DCالقيمةاللغة
dc.contributor.adviserنتو, سمير سليمان أحمد-
dc.contributor.authorراجحي, ياسمين عبدالله يحيى-
dc.date.accessioned2022-02-10T05:25:32Z-
dc.date.available2022-02-10T05:25:32Z-
dc.date.issued2021en_US
dc.identifier.urihttp://dorar.uqu.edu.sa//uquui/handle/20.500.12248/132133-
dc.description98ورقة.en_US
dc.description.abstractUsing an accurate protocols from different associations, organizations, and committees (such as the American Association of Physicists in Medicine (AAPM), the American College of Medical Physics (ACPM), the American College of Nuclear Medicine (ACNM)… etc). Professionally made tools (such as the RaySafe and Fluke Biomedical) and phantoms (such as Pro-Digi phantom, Pro-fluo phantom, CT Dose phantom, CT ACR 464, Mammo 156 Phantom) are required to measure physical parameters of the machines accurately. These parameters include: kilovoltage peak (kVp) - exposure time accuracy and reproducibility - Mill-Ampere Second (mAs) linearity - half value layer (HVL) - typical entrance skin exposure rate (ESER) - collimator leakage - alignment light accuracy - image quality - CT number accuracy - CT number uniformity - slice thickness - low contrast resolution - high contrast resolution - radiation dosimetry - Automatic exposure control (AEC) thickness tracking -detector uniformity - Automatic exposure control (AEC) reproducibility - image quality -contrast noise ratio (CNR) - average glandular dose (AGD). Quality Control (QC) tests were performed in five local hospitals in Makkah city and all Image quality results for all modalities were within the accepted tolerance level. AGD of mammography, the effective dose of CT and typical patient entrance skin exposure rates of both fluoroscopy and C-arm were within the tolerance. Time accuracy in the ordinary X-ray for small focal spot size was -5.85% outside the limit and Mammography kVp accuracy maximum value also was 5.6% outside the limit for small focal spot size. Automatic exposure control (AEC) reproducibility Coefficient of variation (COV) results for mammography was 0.103 where the tolerance is COV < 0.05 and results were outside that.en_US
dc.language.isoانجليزيen_US
dc.publisherجامعة أم القرىen_US
dc.relation.isformatofمكتبة الملك عبدالله بن عبدالعزيز الجامعيةen_US
dc.subjectMedical Physicsen_US
dc.titleضمان الجودة لأجهزة التشخيص الاشعاعي في المستشفياتen_US
dc.title.alternativeQuality Assurance for Diagnostic X-ray Machines in Hospitalsen_US
dc.identifier.callnum42403-
dc.type.formatماجستيرen_US
dc.publisher.countryالمملكة العربية السعوديةen_US
dc.relation.collageالعلوم التطبيقيةen_US
dc.type.statusمجازen_US
dc.rights.holdYesen_US
dc.rights.digitalYesen_US
dc.publisher.cityمكة المكرمةen_US
dc.date.issuedhijri1442en_US
dc.relation.depالفيزياءen_US
dc.rights.digitizedYesen_US
يظهر في المجموعات :الرسائل العلمية المحدثة

الملفات في هذا العنصر:
ملف الوصف الحجمالتنسيق 
24403.pdf
"   الوصول المحدود"
الرسالة الكاملة22.19 MBAdobe PDFعرض/ فتح
طلب نسخة
title24403.pdf
"   الوصول المحدود"
غلاف197.65 kBAdobe PDFعرض/ فتح
طلب نسخة
absa24403.pdf
"   الوصول المحدود"
ملخص الرسالة بالعربي72.06 kBAdobe PDFعرض/ فتح
طلب نسخة
abse24403.pdf
"   الوصول المحدود"
ملخص الرسالة بالإنجليزي56.85 kBAdobe PDFعرض/ فتح
طلب نسخة
indu24403.pdf
"   الوصول المحدود"
المقدمة72.14 kBAdobe PDFعرض/ فتح
طلب نسخة
cont24403.pdf
"   الوصول المحدود"
فهرس الموضوعات191.58 kBAdobe PDFعرض/ فتح
طلب نسخة

تعليقات (0)



جميع الأوعية على المكتبة الرقمية محمية بموجب حقوق النشر، ما لم يذكر خلاف ذلك