D-Library Repositry

//uquui/

Reports Community

Annual Report Collection

 2021

 Thermal Analysis of a Solar-Powered Absorption Air Conditioning System: Case Study for a Tent in Mina Zone, Saudi Arabia

 الجهني, ياسر سالم جزاء


//uquui/handle/20.500.12248/132285
0 Downloads
581 Visits

Thermal Analysis of a Solar-Powered Absorption Air Conditioning System: Case Study for a Tent in Mina Zone, Saudi Arabia

Call Number : 24974
Publisher :جامعة أم القرى
Pub Place : مكة المكرمة
Issue Date : 2021 - 1442 H
Description : 74 ورقة.
Format : ماجستير
Language : عربي
Is format of : مكتبة الملك عبدالله بن عبدالعزيز الجامعية

The present study involved TRNSYS simulation for solar cooling with cold energy storage. It was applied to a hypothetical tent located in the Mina zone, KSA, where millions of Muslim pilgrims stay in these tents for a few days once a year. The required cooling demand was calculated based on Makkah climatic region for a tent that can include 150 persons for 7 days. Using TRNSYS software, the thermal transient model was created. The system consists of a solar thermal collector; absorption cooling chiller, cooling tower, storage tank and fan coil units. The results show that the required cooling capacity for the tent is about 70 kW (20 tons refrigeration) to keep the zone air temperature at 24 °C during summer days. It was also found that the cooling demand for the tent for 7 days in June is around 8,850 kWh. In addition, the effect of cold-water storage on the system performance was studied. Using a chilled water tank of 500 m3 has proved to minimize the absorption chiller capacity from 20 tons to 4.7 ton. Moreover, a PV system was designed to cover the electrical load of the considered absorption.

Title: Thermal Analysis of a Solar-Powered Absorption Air Conditioning System: Case Study for a Tent in Mina Zone, Saudi Arabia
Authors: عابدين, عادل
الجهني, ياسر سالم جزاء
Subjects :: Mechanical Engineering
Issue Date :: 2021
Publisher :: جامعة أم القرى
Abstract: The present study involved TRNSYS simulation for solar cooling with cold energy storage. It was applied to a hypothetical tent located in the Mina zone, KSA, where millions of Muslim pilgrims stay in these tents for a few days once a year. The required cooling demand was calculated based on Makkah climatic region for a tent that can include 150 persons for 7 days. Using TRNSYS software, the thermal transient model was created. The system consists of a solar thermal collector; absorption cooling chiller, cooling tower, storage tank and fan coil units. The results show that the required cooling capacity for the tent is about 70 kW (20 tons refrigeration) to keep the zone air temperature at 24 °C during summer days. It was also found that the cooling demand for the tent for 7 days in June is around 8,850 kWh. In addition, the effect of cold-water storage on the system performance was studied. Using a chilled water tank of 500 m3 has proved to minimize the absorption chiller capacity from 20 tons to 4.7 ton. Moreover, a PV system was designed to cover the electrical load of the considered absorption.
Description :: 74 ورقة.
URI: http://dorar.uqu.edu.sa//uquui/handle/20.500.12248/132285
Appears in Collections :الرسائل العلمية المحدثة

Files in This Item :
File Description SizeFormat 
24974.pdf
"   Restricted Access"
الرسالة الكاملة6.38 MBAdobe PDFView/Open
Request a copy
title24974.pdf
"   Restricted Access"
غلاف144.18 kBAdobe PDFView/Open
Request a copy
absa24974.pdf
"   Restricted Access"
ملخص الرسالة بالعربي29.26 kBAdobe PDFView/Open
Request a copy
abse24974.pdf
"   Restricted Access"
ملخص الرسالة بالإنجليزي42.35 kBAdobe PDFView/Open
Request a copy
indu24974.pdf
"   Restricted Access"
المقدمة1.04 MBAdobe PDFView/Open
Request a copy
cont24974.pdf
"   Restricted Access"
فهرس الموضوعات73.58 kBAdobe PDFView/Open
Request a copy
Add to Auditors PDF citation Digitization Request

Comments (0)



Items in D-Library are protected by copyright, with all rights reserved, unless otherwise indicated.