D-Library Repositry

//uquui/

Reports Community

Annual Report Collection

 2021

 دراسة اختبارات الحريق على نطاق واسع في نفق طريق الملك خالد بمكة المكرمة

 BAGABER, OMAR SAEED


//uquui/handle/20.500.12248/132098
Full metadata record
DC FieldValueLanguage
dc.contributor.adviserGUEDRI, KAMEL-
dc.contributor.authorBAGABER, OMAR SAEED-
dc.date.accessioned2022-02-07T06:57:19Z-
dc.date.available2022-02-07T06:57:19Z-
dc.date.issued2021en_US
dc.identifier.urihttp://dorar.uqu.edu.sa//uquui/handle/20.500.12248/132098-
dc.description79 ورقةen_US
dc.description.abstractTunnel fires have escalated over the past years and have resulted in many disasters. Consequently, tunnel fires must be studied and safety regulations and standards must be introduced to limit these disasters. The experimental tests in tunnel fire give critical results about tunnel fire impact, but unfortunately these tests are very expensive and may cause extensive damage to the tunnel structure. Therefore, large-scale modeling using fire dynamic simulation is one of the best techniques used to limit these costs and losses. Fire dynamic simulation was validated and different simulations were performed to investigate the effect of the thermal attack of the fire on the tunnel. Parametric study of large-scale fire tests in Makkah’ King Khalid Road Tunnel showed that: (1) Increasing heat release rate per unit area (HRRPUA) by 10% raised the radiation by ~30% while decreasing HRRPUA by 5% lowered the radiation by ~50%; (2) Increasing Heat of combustion by 50% raised the radiation and CO and 〖CO〗_2 concentrations by ~17% and ~20%, respectively; (3) Increasing CO-yield by 75% raised CO concentration by ~50% while decreasing CO-yield by 75% lowered CO concentration by ~75%; and (4) Changing soot-yield affected all parameters except the oxygen concentration and air velocity and the most parameter affected by changing soot-yield was the radiation where it was decreased by ~40% with increasing and decreasing soot-yield by 75%. The simulations proved also that increasing ambient temperature from 10.5 °C to 40 °C raised the maximum temperature from 85 °C to ~110 °C and raised the maximum radiation from 30 kW/m2 to ~38 kW/m2. In addition, increasing tunnel height from 9 m to 12 m lowered the radiation by ~50% while the temperature was almost unaffected by changing.en_US
dc.language.isoانجليزيen_US
dc.publisherجامعة أم القرىen_US
dc.relation.isformatofمكتبة الملك عبدالله بن عبدالعزيز الجامعيةen_US
dc.subjectالهندسة الميكانيكيةen_US
dc.titleدراسة اختبارات الحريق على نطاق واسع في نفق طريق الملك خالد بمكة المكرمةen_US
dc.title.alternativeStudy of Large-scale Fire Tests in Makkah’ King Khalid Road Tunnelen_US
dc.identifier.callnum24398-
dc.type.formatماجستيرen_US
dc.publisher.countryالمملكة العربية السعوديةen_US
dc.relation.collageالهندسة والعمارة الإسلاميةen_US
dc.type.statusمجازen_US
dc.rights.holdYesen_US
dc.rights.digitalYesen_US
dc.publisher.cityمكة المكرمةen_US
dc.date.issuedhijri1442en_US
dc.relation.depالهندسة الميكانيكيةen_US
dc.rights.digitizedYesen_US
Appears in Collections :الرسائل العلمية المحدثة

Files in This Item :
File Description SizeFormat 
24398.pdf
"   Restricted Access"
الرسالة الكاملة2.15 MBAdobe PDFView/Open
Request a copy
absa24398.pdf
"   Restricted Access"
ملخص الرسالة بالعربي123.21 kBAdobe PDFView/Open
Request a copy
abse24398.pdf
"   Restricted Access"
ملخص الرسالة بالإنجليزي190.66 kBAdobe PDFView/Open
Request a copy
cont24398.pdf
"   Restricted Access"
فهرس الموضوعات113.05 kBAdobe PDFView/Open
Request a copy
ind24398.pdf
"   Restricted Access"
المقدمة879.13 kBAdobe PDFView/Open
Request a copy
title24398.pdf
"   Restricted Access"
غلاف233.24 kBAdobe PDFView/Open
Request a copy

Comments (0)



Items in D-Library are protected by copyright, with all rights reserved, unless otherwise indicated.