D-Library Repositry

//uquui/

Reports Community

Annual Report Collection

 2021

 نمذجة وتحسين خشونة السطح لطلاء مركب الإيبوكسي / الجسيمات النانوية المستخدمة كطبقة واقية في مجاري المداخن

 Abualsaud, Jaber Mohammed Jaber


//uquui/handle/20.500.12248/131944
Full metadata record
DC FieldValueLanguage
dc.contributor.adviserMohamed, Korrany-
dc.contributor.adviserAhmed, Fathi-
dc.contributor.authorAbualsaud, Jaber Mohammed Jaber-
dc.date.accessioned2021-12-12T07:39:28Z-
dc.date.available2021-12-12T07:39:28Z-
dc.date.issued2021en_US
dc.identifier.urihttp://dorar.uqu.edu.sa//uquui/handle/20.500.12248/131944-
dc.description56 ورقةen_US
dc.description.abstractIn power plants, flue gases cause a severe corrosion damage in its metallic parts such as flue duct, heat exchanger and boiler. Coating still one of the effective techniques to eliminate his damage. A robust fuzzy model of the surface roughness profile such average roughness; Ra and average of ten-point height; Rz of flue gas duct coated by protective composite coating from epoxy and Nano-particles was built based on the experimental data set. The proposed model consists of four different Nano-particles (ZnO, ZrO2, SiO2 and NiO) with 2%, 4%, 6%, and 8%. Response surface methodology (RSM) and Fuzzy logic system approach were used to optimize the process parameters and identify the optimal conditions for minimum surface roughness of this coated duct. In order to prove the superiority of the proposed fuzzy model, the model results are compared with those obtained by ANOVA. The coefficient of determination and the root mean square error (RMSE) are used as metrics of the comparison. For Ra, for the first output response, using ANOVA, the coefficient of determination values is 0.9137 for training value and 0.4037 for prediction value. Similarly, for Rz the second output response, the coefficient of determination results is 0.9695 and 0.4037, respectively, for training and prediction. In the Fuzzy modelling of Ra: the first output response, the RMSE values are 0.0 and 0.1455, respectively, for training and testing. The values for the coefficient of determination are 1.00 and 0.9807, respectively, for training and testing. The obtained results proved the superiority of fuzzy modelling. For modelling the second output response Rz, the RMSE values are 0.0 and 0.0421respectively for training and testing and the coefficient of determination values are 1.00 and 0.9959, respectively for training and testing. The observed R^2 value, adjusted R^2 , predicted R^2 , and F-values indicate that the developeden_US
dc.language.isoانجليزيen_US
dc.publisherجامعة أم القرىen_US
dc.relation.isformatofمكتبة الملك عبدالله بن عبدالعزيز الجامعيةen_US
dc.subjectالهندسة الميكانيكيةen_US
dc.titleنمذجة وتحسين خشونة السطح لطلاء مركب الإيبوكسي / الجسيمات النانوية المستخدمة كطبقة واقية في مجاري المداخنen_US
dc.title.alternativeModelling and Optimization of Surface Roughness of Epoxy/Nanoparticles Composite Coating Used as Protective Layer in Flue Ductsen_US
dc.identifier.callnum24532-
dc.type.formatماجستيرen_US
dc.publisher.countryالمملكة العربية السعوديةen_US
dc.relation.collageالهندسة والعمارة الإسلاميةen_US
dc.type.statusمجازen_US
dc.rights.holdYesen_US
dc.rights.digitalYesen_US
dc.publisher.cityمكة المكرمةen_US
dc.date.issuedhijri1442en_US
dc.relation.depالهندسة الميكانيكيةen_US
dc.rights.digitizedYesen_US
Appears in Collections :الرسائل العلمية المحدثة

Files in This Item :
File Description SizeFormat 
24532.pdf
"   Restricted Access"
الرسالة الكاملة1.58 MBAdobe PDFView/Open
Request a copy
abse24532.pdf
"   Restricted Access"
ملخص الرسالة بالإنجليزي83.34 kBAdobe PDFView/Open
Request a copy
cont 24532.pdf
"   Restricted Access"
فهرس الموضوعات206.64 kBAdobe PDFView/Open
Request a copy
titel24532.pdf
"   Restricted Access"
غلاف9.86 kBAdobe PDFView/Open
Request a copy

Comments (0)



Items in D-Library are protected by copyright, with all rights reserved, unless otherwise indicated.