D-Library Repositry

//uquui/

Reports Community

Annual Report Collection

 2021

 دراسة الجدوى الاقتصادية والتقنية لدمج مياه التغذية المسخنة بالطاقة الشمسية في محطة طاقة بخارية تقليدية

 Hosawi, Yasir Mohammed


//uquui/handle/20.500.12248/131027
Full metadata record
DC FieldValueLanguage
dc.contributor.adviserAbdeen, Adel A.-
dc.contributor.authorHosawi, Yasir Mohammed-
dc.date.accessioned2021-10-21T06:55:20Z-
dc.date.available2021-10-21T06:55:20Z-
dc.date.issued2021en_US
dc.identifier.urihttp://dorar.uqu.edu.sa//uquui/handle/20.500.12248/131027-
dc.description62 ورقةen_US
dc.description.abstractTechnical and economic feasibility of heating feed water of a co-generation power plant through integrate parabolic trough solar collectors has been provided in this work. The extracted steam from steam turbine to the highest-pressure feed water heater is saved by assistance of solar energy, thus decreasing fuel consumption in steam boiler. The study is based on a 62 MW Heavy fuel oil fired power plant for Shoaiba weather conditions. A numerical simulation model was created by TRNSYS simulation software to find the annual performance of the power plant integrated with solar system. The results are validated with the measured data of the conventional power plant. The annual performance of the system is estimated as the average solar power generation and solar fraction in FWH. It was found that Optimum at which the system the maximum LCS was obtained and equal 41.5 $M at 150,000 m2. It can achieve an annual solar fraction of about 28% which 1.72E+11 kJ. Economic feasibility analysis is considered in this work to estimate the life cycle savings (LCS), levelized cost of energy (LCOE) and amount of fuel saved. Based on the economic study, the payback lifetime is about 14.6 years. An economic advantages of reducing the fuel consumption and reducing the CO2 emissions are the main benefits of this study. This study summarized that total of 4,619 tons fuel can be saved and 777.34 tons CO2 can be avoided. It can be concluded that, the integration of higher-pressure feed water heater with solar energy is found feasible in terms of LCS. Same methodology can be applied on other plants arounden_US
dc.language.isoانجليزيen_US
dc.publisherجامعة أم القرىen_US
dc.relation.isformatofمكتبة الملك عبدالله بن عبدالعزيز الجامعيةen_US
dc.subjectالهندسة الميكانيكيةen_US
dc.titleدراسة الجدوى الاقتصادية والتقنية لدمج مياه التغذية المسخنة بالطاقة الشمسية في محطة طاقة بخارية تقليديةen_US
dc.title.alternativeTechno-Economic Feasibility Study of integrating Solar Heated Feed Water to a Conventional Steam Power Planten_US
dc.identifier.callnum24568-
dc.type.formatماجستيرen_US
dc.publisher.countryالمملكة العربية السعوديةen_US
dc.relation.collageالهندسة والعمارة الإسلاميةen_US
dc.type.statusمجازen_US
dc.rights.holdYesen_US
dc.rights.digitalYesen_US
dc.publisher.cityمكة المكرمةen_US
dc.date.issuedhijri1440en_US
dc.relation.depالهندسة الميكانيكيةen_US
dc.rights.digitizedYesen_US
Appears in Collections :الرسائل العلمية المحدثة

Files in This Item :
File Description SizeFormat 
24568.pdf
"   Restricted Access"
الرسالة الكاملة2.4 MBAdobe PDFView/Open
Request a copy

Comments (0)



Items in D-Library are protected by copyright, with all rights reserved, unless otherwise indicated.